Scope. Outdoor design conditions and illustrative block loads for homes in and around Salt Lake City, UT. The example loads are estimates for typical houses, not a design for yours. Your building department may require specific design values. Not ACCA approved or certified, and not a stamped design.
Salt Lake City design conditions
| Weather station | Salt Lake City International Airport (KSLC) |
|---|---|
| Source | NOAA NCEI Engineering Weather Data, 1988–2017 observations |
| Elevation | 4,227 ft |
| 99% heating design temperature (NOAA/ASHRAE) | 14°F |
| 1% cooling design temperature (NOAA/ASHRAE) | 96°F |
| Mean coincident wet bulb | 62°F |
| Design grains (75°F, 50% RH indoors) | -33 |
| Daily range | Medium (July average 25°F) |
| IECC climate zone | 5B (Salt Lake County, 2021 IECC) |
With Manual J’s default indoor conditions of 70°F in winter and 75°F in summer, the heating load is driven by a 56°F difference and the cooling load by a 21°F difference, before sun, people and moisture are added. Design grains are negative, which means the outdoor air at the design condition is drier than the indoor target: the cooling load is almost entirely sensible. At 4,227 feet, Manual J corrects the air density in its infiltration terms, and gas furnaces and fans deliver less than their sea-level ratings.
What drives loads in Salt Lake City
NOAA lists Salt Lake City International at 96°F cooling and 14°F heating, with a July daily range of about 25°F and negative design grains.
Basements and two-story homes are typical along the Wasatch Front. Winter inversions can hold cold air in the valley for days, but the design temperature, not the inversion, is what sizes the heat.
Typical loads for Salt Lake City homes
Four illustrative houses, each with 8-foot ceilings and ducts in the basement unless noted, at the design conditions above:
| House | Heating load | Cooling load | Nominal size | Sq ft per ton |
|---|---|---|---|---|
| Older 1,500 sq ft one-story fair insulation, double-pane windows | 42,395 Btuh | 24,449 Btuh | 2.5 tons | 736 |
| 2,000 sq ft one-story, built to code good insulation, low-E windows | 35,974 Btuh | 21,722 Btuh | 2 tons | 1,105 |
| 2,600 sq ft two-story, built to code good insulation, low-E windows | 40,089 Btuh | 25,155 Btuh | 2.5 tons | 1,240 |
| 2,000 sq ft high-performance excellent insulation and air sealing, ducts inside | 27,898 Btuh | 18,831 Btuh | 2 tons | 1,274 |
The spread is the point. The older 1,500 sq ft house needs 42,395 Btuh of heat, more than the 2,000 sq ft high-performance house at 27,898 Btuh, despite being 500 sq ft smaller. No square-foot rule can see that. These are whole-house block loads from the same engine the free Manual J calculator and the app use; a room-by-room load for a real house will differ.
Common sizing mistakes in Salt Lake City
- Ignoring altitude derating on gas furnaces.
- Using humid-climate cooling assumptions. Evaporative coolers have a long history here for a reason: the air is dry.
- Sizing for the coldest inversion week instead of the 99% design temperature.
Heat pumps in Salt Lake City
At 14°F, cold-climate heat pumps carry most of the heating season; check capacity at 5°F and 17°F and allow for altitude. The cold-climate heat pump guide walks through capacity at the design temperature, the balance point and backup heat.
Run a load for your Salt Lake City house
The free Manual J calculator takes a ZIP code and eight inputs and returns a whole-house heating and cooling load in the browser. The HVAC Load Calculator app goes further at the house: room-by-room loads, Manual S equipment sizes and a PDF report.
FAQ
Do winter inversions change the Salt Lake heating design temperature?
No. Inversions are part of the weather record behind the 99% design temperature, 14°F at the airport. They mean long stretches of steady cold, which favors equipment that runs efficiently at low output.
What is the Manual J design temperature for Salt Lake City, UT?
NOAA’s Engineering Weather Data lists Salt Lake City International Airport at 14°F for the 99% heating design and 96°F for the 1% cooling design, with a 62°F mean coincident wet bulb, from 1988–2017 observations. Use the station closest to the house in climate, and any value your building department requires.
What size AC do I need for a 2,000 sq ft house in Salt Lake City?
It depends on the house, not the floor area. In our example, a code-built 2,000 sq ft one-story with low-E windows and ducts in the basement comes out at about 21,722 Btuh of cooling, a 2-ton nominal size, or about 1,105 sq ft per ton. An older or leakier house needs more; run a load for the actual house.